Supported Combustion Analyzers
Sauermann Si-CA Series (Recommended)
Sauermann combustion analyzers connect directly to measureQuick via Bluetooth Low Energy. Live data streams include:
- CO (carbon monoxide)
- CO2 (carbon dioxide)
- O2 (oxygen)
- Stack temperature
- Draft pressure
- Combustion efficiency
Sauermann instruments meet the ANSI/BPI-1200 accuracy requirements for CO measurement (+/-10 ppm or better).
UEi Personal CO Meter
The UEi personal CO meter connects via BLE for ambient carbon monoxide monitoring. This is a safety device, not a full combustion analyzer.
Not Supported
Fieldpiece Combustion Analyzers
Fieldpiece combustion analyzers are not supported and will not be added to measureQuick. The reason: Fieldpiece ambient CO accuracy is +/-20 ppm, which does not meet the ANSI/BPI-1200 standard requirement of +/-10 ppm. measureQuick requires instruments that meet this accuracy standard for combustion diagnostics.
Bacharach Fyrite Insight / InTech
Previously supported, now sunset. BLE connectivity is no longer maintained in current app versions.
Accutools BluFlame
Previously supported, now sunset.
Other Analyzers
Analyzers from Testo, Flue, Wohler, and other manufacturers are not currently supported for direct Bluetooth connection.
Manual Entry for Unsupported Analyzers
If your combustion analyzer is not supported for Bluetooth connection, you can enter measurements manually:
- Run your combustion test with your analyzer as usual.
- In measureQuick, open the combustion test screen.
- Tap each measurement field and enter the value from your analyzer display.
- The app processes manually entered data the same way it processes Bluetooth data: pass/fail evaluation, report generation, and cloud storage all work normally.
Low-Fire vs High-Fire Testing
measureQuick supports both low-fire and high-fire combustion test modes. Select the appropriate mode when setting up your combustion test. The app adjusts target values based on the selected firing rate.
Related Articles
Still Need Help?
Email support@measurequick.com or call (234) 813-9178 (Monday-Friday, 9am-5pm EST).
Related Articles
Supported Smart Tools & Compatibility
Supported Manufacturers measureQuick connects to smart tools from these manufacturers via Bluetooth Low Energy (BLE): Manufacturer Tool Types Connection Fieldpiece JobLink wireless probes, SMAN manifolds, multimeter Direct BLE Testo Smart Probes, ...
Quick Start: Your First Test in 10 Minutes
What You Need measureQuick installed on your phone (installation guide) A measureQuick account (account setup) Optional: Bluetooth smart tools (Fieldpiece, Testo, NAVAC, etc.). You can also run your first test using Demo Mode or manual entry. Step 1: ...
ACCA QI Setup
What Is ACCA QI? ACCA Quality Installation (QI) verifies that HVAC installations meet ACCA Manuals J (load calculation), S (equipment selection), and D (duct design). measureQuick is the platform for ACCA QI certification. It tracks compliance, flags ...
Login & Account Recovery
Resetting Your Password Open the measureQuick app and tap Forgot Password on the login screen. Enter the email address you used to create your account. Check your email (including spam/junk) for the reset link. Tap the link and set a new password (8+ ...
NCI Air Upgrade Setup
What Is the NCI Air Upgrade? NCI (National Comfort Institute) focuses on HVAC performance testing. Their Air Upgrade program tests airflow at each register to verify conditioned air reaches the rooms it serves. measureQuick integrates with NCI Air ...