Sauermann combustion analyzers connect directly to measureQuick via Bluetooth Low Energy. Live data streams include:
Sauermann instruments meet the ANSI/BPI-1200 accuracy requirements for CO measurement (+/-10 ppm or better).
The UEi personal CO meter connects via BLE for ambient carbon monoxide monitoring. This is a safety device, not a full combustion analyzer.
Fieldpiece combustion analyzers are not supported and will not be added to measureQuick. The reason: Fieldpiece ambient CO accuracy is +/-20 ppm, which does not meet the ANSI/BPI-1200 standard requirement of +/-10 ppm. measureQuick requires instruments that meet this accuracy standard for combustion diagnostics.
Previously supported, now sunset. BLE connectivity is no longer maintained in current app versions.
Previously supported, now sunset.
Analyzers from Testo, Flue, Wohler, and other manufacturers are not currently supported for direct Bluetooth connection.
If your combustion analyzer is not supported for Bluetooth connection, you can enter measurements manually:
measureQuick supports both low-fire and high-fire combustion test modes. Select the appropriate mode when setting up your combustion test. The app adjusts target values based on the selected firing rate.
For the full list of supported Bluetooth instruments, see Supported Smart Tools & Compatibility. To pair your analyzer, see How to Pair Bluetooth Tools.
Email support@measurequick.com or call (234) 813-9178 (Monday-Friday, 9am-5pm EST).